Heart Rate LCD Display Multi Parameter Patient Monitor Quality guaranteed
Power
Supply power | AC 220V±10% 50/60Hz±2% |
power | 80VA |
Fuse specifications and models, rating | T2.5AL/250V Φ5×20 |
Display mode | LCD display |
Alarm mode | Audible and visual |
Network connection | Can be expanded |
ECG
Lead | Standard Three leads | R,L,N, lead mode :Ⅰ,Ⅱ,Ⅲ | |
Standard Five leads | R,L,F,N,C, Lead mode :Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V; | ||
Sensitivity | 2.5mm/mV,5mm/mV,10mm/mV,20mm/mV,erro≤±3% | ||
Scan speed | 12.5,25,50mm/s three level,erro ≤±10% | ||
Inner voice | <30μVP-P | ||
input impedance | ≥5MΩ | ||
input loop current | ≤0.1μA | ||
endure electrode polarizing voltage | ±300mV | ||
Frequency property | diagnosis mode 0.05~130HZ monitoring mode 0.5~40HZ operating 1~20HZ | ||
CMRR | Diagnosis mode ≥90dB Monitoring mode ≥100dB Operating mode ≥100dB | ||
HR measurement range | Adult 15~300bpm Neonate /pediatrics 15~350bpm | ||
HR accuracy | ±2% | ||
alarm range | 0~301bpm, upper and lower limit can be adjusted continuously | ||
alarm indicator | Audial and visual alarm | ||
protection | Isolated immunity voltage 4000V, Immunity of electronic surgical Anti-defibrillation | ||
protection and recovery for defibrillation effect | In the monitor and the surgical model ,ECG waveforms recovery to baseline in 5S. | ||
Electrode polarization recovery time after the fibrillation | In the monitor and the surgical mode ,ECG waveforms recovered to baseline in 10S. | ||
measurement mode | Diagnosis mode,monitoring mode,operation mode | ||
pace marker pulse detection and suppressing | width | ±2mV~±700mV | |
broadband | 0.1ms~2ms | ||
risetime | 10μs~100μs | ||
ECG signal input range | -8.0mV~+8.0mV | ||
HR sensitivity | >200μV |
Battery
Battery type | rechargeable li-ion battery 12V/2300mAH |
Recharge time | ≥4 hour |
Use time | ≥120 minute |
NIBP
measurement range | adult | systolic pressure | 40~270mmHg |
diastolic pressure | 10~215mmHg | ||
mean pressure | 20~235mmHg | ||
pediatrics | systolic pressure | 40~200mmHg | |
diastolic pressure | 10~150mmHg | ||
mean pressure | 20~165mmHg | ||
neonate | systolic pressure | 40~135mmHg | |
diastolic pressure | 10~100mmHg | ||
mean pressure | 20~110mmHg | ||
measurement precision | ±5mmHg | ||
display unit | mmHg,Kpa | ||
alarm range | Systolic pressure | 0~301mmHg,upper and lower limit can be adjusted continuously | |
diastolic pressure | 0~301mmHg,upper and lower limit can be adjusted continuously | ||
alarm indicator | Audial and visual | ||
measurement mode | adult | Single , cycle, speedy | |
pediatrics | Single, cycle,speedy | ||
neonate | single,cycle | ||
static pressure range | 0~300mmHg | ||
static pressure precision | ±3mmHg | ||
pulse measurement range | 40~240bpm | ||
protection adult | Dual hardware,software overpressure protection 300mmHg | ||
Period measurement time interval (minute) | 1,3,5,10,15,30,60,90,120,180,240,480 |
Sp02
SpO2 measurement range precision | 0~100% ±2%(70~100% ) |
PR measurement range precision | 20~300 bpm ±2% |
Alarm range | 0~100%,upper and lower limit can be adjusted continuously |
Alarm indicator | Audial and visual alarm |
RESP
Measurement range | adult 7~120 bpm pediatric /neonate 7~150 bpm |
precision | ±2bpm |
impedance test range | 0.3~3Ω |
base line impedance range | 200~4000Ω(50~120kHz pump-frequency) |
apnea alarm time | 10~40s |
alarm range | 0~121bpm, up and down limit can be adjusted continuously |
alarm indicator | Audial and visual alarm |